{"product_id":"18kw-48v-commercial-three-phase-all-in-one-solar-charge-inverter-powercore-18k-48","title":"SunGoldPower 18kW 48V Commercial Three-Phase All-in-One Solar Charge Inverter PowerCore 18K-48","description":"\u003cp\u003eThis is a commercial three-phase inverter, and that makes it a fundamentally different installation from every residential split-phase unit in this range. The specification table gives the rated output voltage as 120\/208Vac (L1+L2+L3+N+PE), held to plus or minus 5%, so the unit is built for a three-phase electrical service. It is NOT a drop-in alternative to a 120\/240V split-phase inverter, and a home on ordinary single-phase split-phase service cannot use it. The supplier is consistent on this point across its product title, its page title and its product copy, and the specification confirms it. Check your service is three-phase before going any further.\u003c\/p\u003e\u003cp\u003eWithin that scope it is a capable off-grid machine, and the specification table now says so in detail. Rated output power is 18000W with a maximum peak power of twice rated power for 10 seconds, a maximum AC output power of 19800VA and a rated AC output current of 50.0Aac, with 1 to 6 units in parallel. PV comes in on two MPPT trackers taking 14.4kW each, 28.8kW in total, at up to 600Vdc with a 120-550Vdc operating window, a 100Vdc start-up voltage and 36Adc per tracker. The battery side is a 48Vdc system with a 40-60Vdc range, charging and discharging at up to 360Adc whether from PV or from grid and generator, on a three-stage curve with equalisation and a self-adaption mode for a lithium BMS. A grid and generator input is documented as well - 120\/208Vac rated, with a 90-140Vac phase voltage range, a 156-242Vac line voltage range and a 100A bypass overload current - so utility power can be brought in as a source even though no export or grid-tie capability is claimed anywhere. Efficiency is 97.6% maximum with MPPT tracking above 99%, the enclosure is IP20 for indoor use only, the unit weighs 118 lbs and measures 23.36 x 33.40 x 8.47 inches, and cooling is intelligent air cooling at under 60dB. The premises the supplier has in mind are light industrial units, small commercial buildings, workshops and farms, and the loads it names are the kind those places run: water pumps, compressors, refrigeration plant, ventilation fans, lighting and a building's own essential services. Critical loads sit on the primary AC connection. The second one, labelled GEN\/smart load, is programmable - it serves either as an input for a generator or as a smart-load output, whichever you configure, but only ever one of the two at a time.\u003c\/p\u003e\u003cp\u003eTwo things still need establishing before specifying it. The supplier publishes no per-phase output figure: the specification gives only whole-unit values, a rated AC output current of 50.0Aac and a maximum AC output power of 19800VA, and the manual's overload protection is defined by total load percentage rather than per phase. The 18kW should therefore be understood as a combined total across all three phases rather than a figure available on any one of them, and if your load is unbalanced, or concentrated on a single phase, get the per-phase limit in writing first. The certification position also needs stating precisely. The manual's own certification row names IEC 62109-1, IEC 62109-2 and UL 1741 for safety, with EN 61000-6-1, EN 61000-6-3 and FCC 15 class B for EMC and RoHS - but that is a manufacturer statement inside its own document, with no certificate supplied. It is the weakest basis for a UL 1741 claim anywhere in this brand's range, where the other UL 1741 claims have an Intertek or SGS certificate behind them, and it is not third-party certification. On a unit intended for commercial premises, where an inspector or an insurer will ask for a listing, that distinction matters: ask the supplier for a certificate before quoting it. Supplied as the inverter alone, with no battery, panels, cabling, breakers, disconnects or mounting hardware.\u003c\/p\u003e\u003ch3\u003eThree-Phase Service Required\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThis inverter's rated output voltage is 120\/208Vac (L1+L2+L3+N+PE) and it requires a three-phase electrical service\u003c\/li\u003e\n\u003cli\u003eIt is not interchangeable with the 120\/240V split-phase inverters elsewhere in this range\u003c\/li\u003e\n\u003cli\u003eA standard residential single-phase split-phase service cannot use it\u003c\/li\u003e\n\u003cli\u003eConfirm your service configuration with your electrician or utility before ordering\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNot Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBatteries - the specification gives a 48Vdc system with a 40-60Vdc range, but no compatible battery model is named\u003c\/li\u003e\n\u003cli\u003eSolar panels\u003c\/li\u003e\n\u003cli\u003eBattery and PV cabling, lugs and conduit - note a 48V bank supplying 18kW draws very high DC current\u003c\/li\u003e\n\u003cli\u003eBreakers, fuses and DC or AC disconnects\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003cli\u003eGenerator - the GEN port is a connection point, not a generator or controller\u003c\/li\u003e\n\u003cli\u003eParallel and communication cabling - not listed as supplied, despite paralleling being advertised\u003c\/li\u003e\n\u003cli\u003eWi-Fi or 4G monitoring - the specification lists WiFi as an internal interface and a WiFi or 4G stick as an optional external module, but neither is stated to be supplied\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConfirm Before You Order\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe per-phase output limit is not published - essential if your load is unbalanced\u003c\/li\u003e\n\u003cli\u003eThe only safety standards named are in the manufacturer's own certification row - IEC 62109-1, IEC 62109-2 and UL 1741 - with no certificate document supplied; ask for one before a commercial installation\u003c\/li\u003e\n\u003cli\u003ePV is two MPPT trackers at 14.4kW each, up to 600Vdc, with a 120-550Vdc window, a 100Vdc start-up voltage and 36Adc per tracker\u003c\/li\u003e\n\u003cli\u003eThe battery is a 48Vdc system with a 40-60Vdc range and up to 360Adc charge and discharge; the DC cabling, busbar and fusing requirements are still not specified\u003c\/li\u003e\n\u003cli\u003eIP20, for indoor use only - 118 lbs, 23.36 x 33.40 x 8.47 inches, 97.6% maximum efficiency\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SunGoldPower","offers":[{"title":"Default Title","offer_id":68055603544255,"sku":"PowerCore 18K-48","price":3596.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/1967\/6351\/files\/PowerCore-18K-01.jpg?v=1795100566","url":"https:\/\/adventuremotion.com\/products\/18kw-48v-commercial-three-phase-all-in-one-solar-charge-inverter-powercore-18k-48","provider":"Adventure Motion","version":"1.0","type":"link"}